12.1

Visualisation on the controller: local and remote

A visualisation can either run locally on a controller, or via remote connection on an additional

controller.
The following cases are distinguished:

Local visualisation - integrated control system

Control and visualisation on the same controller. The following runs on the controller:

»VisiWinNET®« runtime, PLC (Logic/Motion), the data manager, and the fieldbus driver.
Local visualisation can be carried out...

• on a panel controller.
• on a cabinet controller with a connection facility for a monitor panel.

Remote access - external visualisation

Control and visualisation on separate controllers.
The »VisiWinNET®« runtime runs on a separate "Visu" controller. This controller solely

undertakes visualisation tasks. The external "Visu" controller accesses the process data of an

additional controller which controls the system.
The control program runs on the first controller. The »VisiWinNET®« runtime runs on the second

controller.

• External "Visu" on the controller
• External "Visu" on a Windows® XP or Windows® Embedded XP PC.