13

Parameter reference

13.5

EtherCAT

167

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C286/12

C286/13

C286/14

Parameter | Name:

C286/12 | ECAT counter: acyclical frames

Data type: UNSIGNED_32

Index: 24289.12

d

=

0x5EE1.0x0C

h

Number of acyclical frames
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C286/13 | ECAT counter: acyclical datagrams

Data type: UNSIGNED_32

Index: 24289.13

d

=

0x5EE1.0x0D

h

Number of acyclical datagrams
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C286/14 | ECAT: Reset individual counters

Data type: UNSIGNED_32

Index: 24289.14

d

=

0x5EE1.0x0E

h

Reset frame and datagram counters (C1086/7 ... 13)
Selection list

(Lenze setting printed in bold)

0 No Operation
1 Reset - All counters
2 Reset - Tx frame counters
4 Reset - Rx frame counters
8 Reset - Lost frame counters

16 Clear Cyclical Frame Counter
32 Clear Cyclical Datagram Counter
64 Reset - Acyclic frame counters

128 Reset - Acyclic datagram counters

Read access  Write access  CINH  PLC-STOP  No transfer