13.2

Basic parameters of the Controllers 3200 C/c300 and p300/p500

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C0148

C0150

C0151

C0152

C0153

C0154

Parameter | Name:

C0148 | WinCE users: User 7 with telnet permissions

Data type: UNSIGNED_8

Index: 24427

d

= 5F6B

h

User may use telnet
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0150 | WinCe users: User name 8

Data type: VISIBLE_STRING

Index: 24425

d

= 5F69

h

Name of the user

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0151 | WinCe users: Password 8

Data type: VISIBLE_STRING

Index: 24424

d

= 5F68

h

Password of the user

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0152 | WinCE users: User with 8 FTP permissions

Data type: UNSIGNED_8

Index: 24423

d

= 5F67

h

User may use FTP
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0153 | FTP: Permissions user 8

Data type: UNSIGNED_32

Index: 24422

d

= 5F66

h

FTP rights of the user.
Value is bit-coded:

Bit 0 Allow Read
Bit 1 Allow Write
Bit 2 Virtual Roots
Bit 3 Allow Hidden Files

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0154 | FTP: Home user 8

Data type: VISIBLE_STRING

Index: 24421

d

= 5F65

h

Home directory of the user

Read access  Write access  CINH  PLC-STOP  No transfer