13 parameter reference – Lenze c300 User Manual

Page 169

Advertising
background image

13

Parameter reference

13.6

Monitor panel (integrated/external)

169

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C0424

C0425

C0426

C0432

Parameter | Name:

C0424 | Automatic dimout: Switch-on after

Data type: UNSIGNED_8

Index: 24151

d

= 5E57

h

Enter the time until automatic dimout of the display. The values range between ...

• ... 0 (maximum value = no dimout of the display) and

• ... 255 (minimum value)

Note:

To deactivate an active dimout of the display, an entry must be made (by activation of the touch display/mouse-

click/shortcut). Then the controller is ready to accept input.

This is why the first entry only result in a deactivation of the dimout if this function is active. Afterwards further

entries are possible.

Setting range

(min. value | unit | max. value)

Lenze setting

0

min

255 0 min

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0425 | Automatic dimout: Brightness value

Data type: UNSIGNED_8

Index: 24150

d

= 5E56

h

Brightness value of the monitor panel in its dimmed state after automatic dimout in [%].

Applies to the integrated monitor panel (panel controller).

Setting range

(min. value | unit | max. value)

Lenze setting

10

%

80 10 %

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0426 | Brightness: Actual value

Data type: UNSIGNED_8

Index: 24149

d

= 5E55

h

Actual brightness value of the monitor panel in [%]

Applies to the integrated monitor panel (panel controller).

Setting range

(min. value | unit | max. value)

Lenze setting

10

%

100 100 %

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0432 | F1 key: Function

Data type: UNSIGNED_32

Index: 24143

d

= 5E4F

h

Function assignment of the F1 key. The individual functions are assigned from a selection list.

Applies to external monitor panels with function keys.

Selection list

(Lenze setting printed in bold)

Info

0 None
1 Start program
2 Touch keyboard
3 Right-hand mouse button
4 Execute AP script
5 Start control panel

Read access  Write access  CINH  PLC-STOP  No transfer

Advertising