Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

174

13

Parameter reference

13.8

Backup&Restore

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.8

Backup&Restore

In this chapter, all parameters for carrying out a »Backup & Restore« (using »WebConfig«) are listed

in numerically ascending order.

C0809

C0810

C0811

C0813

Parameter | Name:

C0809 | Select a main action for the Lenze software

Data type: UNSIGNED_16

Index: 23766

d

= 5CD6

h

Selection list

(Lenze setting printed in bold)

Info

0 Backup

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0810 | Select a main action for the Lenze software

Data type: UNSIGNED_16

Index: 23765

d

= 5CD5

h

Carry out a backup or restore by means of the WebConfig.
Selection list

(Lenze setting printed in bold)

Info

2 Restore

Carry out restore:

• Select the process to restore the data base of a backup

at an individual L-force Controller.

3 Auto restore

Carry out auto restore:

• Restore (restore of a backup) at any number of L-force

Controllers.

• If you connect the USB stick to another L-force

Controller, the same process is carried out

automatically (standard set-up).

4 Update

Carry out update:

• The software of the L-force Controller is updated (the

data is transferred from the USB stick to the internal

flash memory of the L-force Controller).

5 Auto update

Carry out auto update:

• Multiple restore of an update at any number of L-

force Controllers.

• If you connect the USB stick to another L-force

Controller, the same process is carried out

automatically (standard set-up).

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0811 | Assign a name for the backup

Data type: VISIBLE_STRING

Index: 23764

d

= 5CD4

h

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0813 | Display of the backup or update files

Data type: UNSIGNED_16

Index: 23762

d

= 5CD2

h

Selection list

(Lenze setting printed in bold)

Info

1 Display 1 to 10
2 Display 11 to 20
3 Display 21 to 30

Read access  Write access  CINH  PLC-STOP  No transfer

Advertising