6 monitor panel (integrated/external), Monitor panel (integrated/external), 13 parameter reference – Lenze c300 User Manual

Page 168

Advertising
background image

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

168

13

Parameter reference

13.6

Monitor panel (integrated/external)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.6

Monitor panel (integrated/external)

This chapter lists all parameters of the monitor panel (panel controller) and the parameters of an

external, optional panel in numerically ascending order.
The parameters are available depending on the panel variant.

C0420

C0421

C0422

C0423

Parameter | Name:

C0420 | Panel: Width

Data type: UNSIGNED_16

Index: 24155

d

= 5E5B

h

Horizontal resolution of the panel
Display range

(min. value | unit | max. value)

160

2400

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0421 | Panel: Height

Data type: UNSIGNED_16

Index: 24154

d

= 5E5A

h

Vertical resolution of the panel
Display range

(min. value | unit | max. value)

100

2000

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0422 | Dimout: Actual value

Data type: UNSIGNED_8

Index: 24153

d

= 5E59

h

Enter the actual brightness value of the display. The numerical value ranges from the

• Maximum = 0 and the

• Minimum = 63

Setting range

(min. value | unit | max. value)

Lenze setting

0

63 0

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0423 | Brightness: Upper limit

Data type: UNSIGNED_8

Index: 24152

d

= 5E58

h

Enter the maximum brightness value of the display. The numerical value ranges from the

• Maximum = 0 and the

• Minimum = 63

Setting range

(min. value | unit | max. value)

Lenze setting

0

63 0

Read access  Write access  CINH  PLC-STOP  No transfer

Advertising
This manual is related to the following products: