Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

32

5

Commissioning the controller

5.3

Starting the controller

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.3

Starting the controller

The SD card and the internal flash memory are the storage media of the controller. Depending on

the device, the SD card can be used optionally. Detailed information can be found in the device-

specific operating instructions.
The controller saves the user data (like projects and individual data) on the SD card. The operating

system and the Lenze software are saved in the internal flash memory.

Error case: Controller c300/p300 does not start
In case the Controller c300 or p300 does not start, the Lenze standard settings can be activated

using the reset pushbutton.

How to activate the Lenze standard settings:

1. Switch off voltage supply.
2. Press reset pushbutton.
3. While pressing the reset pushbutton, switch on the voltage supply and keep the reset

pushbutton pressed for at least 10 s.

• If the error LED is blinking (green/red) after this action, a manual mains switching is

required.

• The Controller has to be disconnected from the mains until all LEDs go off.

Note!

During the starting process of the controller
If a non-bootable USB flash drive is connected during the starting sequence, it will be

stopped!

• Remove the USB stick and restart the Controller.
• Alternatively, the USB stick can be prepared using the »Backup & Restore« software.

Further information can be found in the online help of the »Backup & Restore«

software.

When the controller is running
Removal of the SD card will lead to a system failure!

• The SD card must not be removed while the controller is running (no "Hot Plugging"

of the SD card possible).

• The SD card is required for the system start since it contains the system files for the

starting process.

Note!

The standard-IP address of the controller is 192.168.5.99 (Lenze setting)
The preset IP configuration can be changed in the »WebConfig«.

Setting IP addresses on the Engineering PC (example: Windows® XP)

( 46)

Entering the IP address of the controller

( 33)

After 15 seconds, the network configuration dialog box will close automatically; the

controller continues with the starting process.