5

Commissioning the controller

5.4

Configuring the controller

35

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.4.2.2

Cabinet Controller without external monitor panel (c300/3221 C)

To configure a Cabinet Controller without a connected monitor panel (e.g. Controller 3221 C), a PC/

laptop with the suitable addresses (IP address, subnet mask, default gateway) is required.

• Connect the PC/laptop to the controller by means of a "crossed" network cable.
• Change the settings on an HTML compliant browser:

Setting IP addresses on the Engineering PC (example: Windows® XP)

( 46)

• Connection establishment: enter the IP address of the controller in the browser: 192.168.5.99

(Lenze default setting).

• In »WebConfig«, click the Ethernet button.
• Enter the desired IP address, subnet mask and default gangway of the Controller.
• Click Accept & Save all.
• Set Use IP configuration to the value "Activate device".
• Click again Accept & Save all in order to save the network settings permanently.