92

11

Remote maintenance and diagnostics

11.5

Activate Windows® CE interface

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.5

Activate Windows® CE interface

During normal operation the Windows® CE functions are hidden on the controller. All controller

functions can be controlled via the Engineering PC.

• For diagnostic purposes and maintenance activities you can use the standard functions of the

controller operating system Windows® CE.

• You can access the Windows® CE functions

• via the service mode if the controller is operated directly,
• via a telnet connection with the corresponding administrator rights.

How to activate the user interface of Windows® CE on the controller:

1. Activate the service mode by keeping the <Shift> key pressed. There are two possibilities of

activating the service mode:

<Shift>+<F4> starts the Control panel. The entry can be made via the on-screen keyboard

or via an optionally connected keyboard.

• When the green LED is blinking, you can start the Control panel with function key

<F1> on the monitor panel.

2. Start the Service command by double-click.
3. Activate the task bar by entering explorer in the command line box.

The task bar facilitates the navigation by providing the basic functions of Windows® CE:

Note!

In order to be able to use a telnet connection, you have to provide a telnet authorisation

to the corresponding Windows® CE user.