8-8 Application Examples
1747-ASB module 2 controls the following I/O modules:
•
1746-OA8, 8-point AC output module
•
1746-IO12, 6-point input/output module
•
1746-IA16, 16-point AC input module
The application is illustrated below. When the switch is closed, bulbs
1 and 2 turn on and an analog signal is moved to analog module
output 1, which leads to the meter.
SLC 5/02
1746-OW8
1746-IA8
1747-SN
ASB 1
17460NIO4I
1746-IV32
1746-OV32
1746-OB16
1746-OA16
ASB 2
1746-OA8
1746-IO12
1746-IA16
EMPTY
The meter is connected
to output 1.
The switch is connected
to input 17.
Bulb 2 is connected
to output 12.
Bulb 1 is connected
to output 4.