Primary chassis complementary chassis, Logical rack 0 logical rack 1 – Rockwell Automation 1747-ASB Remote I/O Adapter User Manual

Page 62

Advertising
background image

Publication 1747-UM006B-EN-P - June 2003

4-8 Configuration

0

1

2

3

4

5

6

7

8

Slot Pair

1

2

3

4

I

I

I

I

O

O

O

O

O

O

O

O

O

I = Input Module

= Output Module

Input Image

Output Image

= unused

image
space

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

1

Slot Pair

2

3

4

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

1

2

3

4

Input Image
from Primary Chassis

Output Image
from Primary Chassis

Output Image
from Complementary Chassis

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 7

Slot 7

Input Image
from Complementary Chassis

Slot

Primary Chassis

Complementary Chassis

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

1

2

3

4

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

1

2

3

4

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 7

Slot 7

Primary Chassis I/O Image

Complementary Chassis I/O Image

Scanner’s I/O Image

1

2

3

4

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 7

Slot 7

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

1

2

3

4

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Group 0

Group 2

Group 4

Group 6

Group 1

Group 3

Group 5

Group 7

Group 0

Group 2

Group 4

Group 6

Group 1

Group 3

Group 5

Group 7

Both images are overlapped in the
scanner. The overlapped image
appears where the primary chassis
image is configured to reside.

In this case, the primary chassis
image is configured as starting
logical rack 0 and starting logical
group 0.

I

I

I

I

Primary Chassis Configured As:

Logical Rack Number 0

Logical Group Number 0

Image Size (logical groups) 16

Addressing Mode 1/2-slot

Primary/Complementary Primary

Complementary Chassis Configured As:

Logical Rack Number 8 (decimal)

Logical Group Number 0

Image Size (logical groups) 16

Addressing Mode 1/2-slot

Primary/Complementary Complementary

Logical

Rack 0

Logical

Rack 1

0

7

8

15

7

0

10

17

Decimal

Octal

0

7

8

15

7

0

10

17

Decimal

Octal

0

7

8

15

7

0

10

17

Decimal

Octal

0

7

8

15

7

0

10

17

Decimal

Octal

0

7

8

15

7

0

10

17

Decimal

Octal

0

7

8

15

7

0

10

17

Decimal

Octal

Slot Pair

Slot Pair

Slot Pair

Slot Pair

Slot Pair

0

1

2

3

4

5

6

7

8

Slot Pair

1

2

3

4

Slot

Advertising