STATION MESSAGES

HEX

CODE

TYPE

PROBLEM

CORRECTIVE ACTION

6A

N

AWAITING RELEASE OF ALL ACTIVE RUN BUTTONS"

OCCURS UNDER THE FOLLOWING CONDITIONS:

1. If after pressing 1 active run button and then not pressing all

active run buttons within 5 seconds. After an additional 5

seconds the message will occur.

2. During single stroke mode and at the end of a normal stroke,

the PM is looking for all active run buttons to be released within

1 second of deĆenergizing clutch valve outputs.

3.

After the arm continuous button is released, if all

active station run buttons are not released within 0.1 second.

IN GENERAL, THESE MESSAGES OCCUR TO PREVENT THE

FOLLOWING:

1 ANTIĆTIE DOWN Ć The PM requires that both buttons be

released if both were pressed and then one has been

released. There is no time delay for this condition to cause a

trip message. The PM also requires that once one button is

pressed, the other button needs to be pressed within 0.5

seconds to continue to operate without a problem.

2. Indication of change in the station active/bypass state or

nc/no contact wiring.

Check for proper wiring of station run buttons. Check for

proper operation of run button contacts.

6B

N

AWAITING RELEASE OF BOTH INCH BUTTOns.

You must press, release, and press again both INCH

buttons before PM can allow further press motion.

6C

N

AWAITING RELEASE OF ARM CONTINUOUS BUTTON.

After releasing the ARM CONTINUOUS button, you have 5

seconds to press all RUN buttons before the PM can enter

continuous mode.

6D

N

CONTINUOUS CYCLE NOT ARMED.

You cannot enter continuous mode until you press the

ARM CONTINUOUS button. You must release it before

pressing all RUN buttons within 5 seconds.

6E

N

AWAITING PC TO INHIBIT STOPĆONĆTOP SIGNAL.

The PM module is still receiving the STOPĆONĆTOP

command. It must cease before the PM can enter

continuous mode. Check your ladder logic (figure 4.6, 4.7,

or 4.8).

6F

N

AWAITING RELEASE OF ALL STOPĆONĆTOP BUTTONS.

You must release the STOPĆONĆTOP buttons of all active

stations before the PM can start any press motion resulting

from pressing RUN buttons.