Figure 6.12, Figure 6.12. directly wire station 2 according to, Field wiring arm connections chapter 6 – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 78

Advertising
background image

Field Wiring Arm Connections

Chapter 6

6Ć26

Figure 6.12

Connections for Operator Stations 3 and 4, and Dummy Plugs

2L2

Chassis A

2L2

Chassis B

Slot 0

Ch A-0

Ch B-1

Ch A-2

Left Run

Left Active

Left 2L1

Ch B-0

Ch A-1

Ch B-2

Right Run

Right Active

Right 2L1

Stop-On-Top

E-stop

Dummy Plug

for Station

Bypass

See figure 6.10

See figure 6.1 or 6.5

2L1

Ch A-3

Ch B-4

Ch A-5

Left Run

Left Active

Left 2L1

Ch B-3

Ch A-4

Ch B-5

Right Run

Right Active

Right 2L1

Stop-On-Top

E-stop

Dummy Plug

for Station

Bypass

Plug-in

Operator

Station 4

See figure 6.10

See figure 6.1 or 6.5

2L1

Ch A-0

Ch A-1

Ch A-2

Ch A-3

Ch A-4

Ch A-5

Ch B-0

Ch B-1

Ch B-2

Ch B-3

Ch B-4

Ch B-5

Plug either the operator station

or dummy plug into the control panel.

17880

A
0
1
2
3
4
5
6
7

A
0
1
2
3
4
5
6
7

IMPORTANT:For These Connections

See Figures

E - STOP

STOP-ON-TOP

6.1 or 6.5

6.10

Plug-in

Operator

Station 3

B

B

1771-IA

Module Group 1

Advertising