PC Ladder Programming

Chapter 4

4Ć16

Function or Command

Description

Operating Mode

Interrupted stroke

Continuous

If an operator releases a RUN button during a down stroke, the

press stops immediately. If within five seconds of stopping, an

operator releases both RUN buttons and presses them again,

the press continues the downstroke. If more than five seconds

elapses, the operator must inch the press to top, select

continuous mode, and follow the first Continuous procedure

above..

Interrupted stroke

SingleĆstroke

Same as Continuous mode except there is no time limit on

reĆapplying the RUN button.

AntiĆtieĆdown

All

The press will not start if you tie down one or more RUN

buttons. After all RUN buttons are released, the operator must

press both RUN buttons at a station simultaneously, and/or

operators at active stations must press all RUN buttons within

five seconds of each other to start the press.

The same applies to the pair of INCH buttons.

AntiĆrepeat

SingleĆstroke

The press is limited to a single stroke, even if the operator

continues to press both RUN buttons. The operator must

release both RUN buttons and press them again to start press

motion.

Inch

The same applies to a pair of INCH buttons as described for

SingleĆstroke.

Motion detector

SingleĆstroke

Continuous

The clutch/brake controller detects press motion using your

motion detector which provides a 120AC input signal. This is a

configurable option.

TopĆstopĆCheck

All

The clutch/brake controller signals a worn or faulty brake by

monitoring the TopĆstopĆcheck cam inputs. Should it see the

TopĆstopĆcheck cam closed after a normal cycle stop has been

initiated and before the press comes to a top stop, it prevents

the press from restarting and energizes the brakeĆfault output.