Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 138
I/I/O From/To Lists
Appendix B
BĆ8
I/O From/To List for Figure 6.15
Operator Station 3
From
To
A100
Left RUN button (NC) contact)
A101
Right RUN button (NO) contact
A102
Left Active jumper conection
A10B
2L2
B100
Right RUN button (NC) contact
B101
Left RUN button (NO) contact
B102
Right Active jumper conection
B10B
2L2
I/O From/To List for Figure 6.16
Operator Station 4
From
To
A103
Left RUN button (NC) contact)
A104
Right RUN button (NO) contact
A105
Left Active jumper conection
B103
Right RUN button (NC) contact
B104
Left RUN button (NO) contact
B105
Right Active jumper conection
I/O From/To List for Figure 6.17
Main and Auxiliary Valve Stem,
Motion Detector, and Air Pressure Switches
From
To
A200
Switch on Main Valve Stem A
A201
Motion Detector A
A201
B201 (make this connection when NOT using Motion Detector B)
A202
Air Pressure Switch A
A202
B202 (make this connection when NOT using AIr Pressure Switch B)
A207
Switch on Auxiliary Valve Stem A
B200
Switch on Main Valve Stem B
B201
Motion Detector B (if used)
B202
AIr Pressure Switch B (if used)
B207
Switch on Auxiliary Valve Stem B