Voting Processor Firmware
Chapter 5
5Ć10
Figure 5.5
Operational Sequence for Starting Continuous Mode
Select continuous mode
Is the barrier guard closed?
Is the shaft in the nearĆtop
position?
Have all operators released all
STOPĆONĆTOP buttons?
Have all operators released all
RUN buttons?
NOTE: The arming sequence guards against accidently starting operation in continuous mode.
12264
Yes
Yes
Select inch mode and position the
shaft to the nearĆtop position
No
Yes
Has an operator pressed the ARM
CONTINUOUS button?
Have 5 seconds elapsed since
pushing ARM CONTINUOUS?
Has each operator pressed his
RUN buttons simultaneously, and
within 5 seconds for all stations?
Go to First Downstroke
No
Yes
No
No
Yes
Yes
No
Yes
No
No
Arming Sequence
Main Motor Forward
No
Yes