Voting Processor Firmware

Chapter 5

5Ć10

Figure 5.5

Operational Sequence for Starting Continuous Mode

Select continuous mode

Is the barrier guard closed?

Is the shaft in the nearĆtop

position?

Have all operators released all

STOPĆONĆTOP buttons?

Have all operators released all

RUN buttons?

NOTE: The arming sequence guards against accidently starting operation in continuous mode.

12264

Yes

Yes

Select inch mode and position the

shaft to the nearĆtop position

No

Yes

Has an operator pressed the ARM

CONTINUOUS button?

Have 5 seconds elapsed since

pushing ARM CONTINUOUS?

Has each operator pressed his

RUN buttons simultaneously, and

within 5 seconds for all stations?

Go to First Downstroke

Figure 5.6

No

Yes

No

No

Yes

Yes

No

Yes

No

No

Arming Sequence

Main Motor Forward

No

Yes