Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 112

Advertising
background image

Troubleshooting

Chapter 7

7Ć28

Diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by

displaying the corresponding data table word using the industrial terminal.

Use this table in conjunction with figure 7.1 and figure references shown in parentheses.

Type of Message

N = NonĆlatched

L = Latched

T = Trip

Condition

Code

P = at PowerĆup

Alt = Alternate chassis

Ethr = Either chassis

Top = Top chassis

Bot = Bottom chassis

Hex

Code

Diagnostic Message (figure References)

Type

50

Swingarm power absent

51

N

INCH button not released. Check (NO) contacts.

52 Alt

N

INCH button not released. Check (NO) contacts.

53

N

INCH button not released. Check (NC) contacts.

54 Alt

N

INCH button not released. Check (NC) contacts.

55

P

N

INCH button not released. Check (NC) contacts.

56

P,

Alt

N

INCH button not released. Check (NC) contacts.

57

P

N

INCH button not released. Check (NC) contacts.

58

P,

Alt

N

INCH button is not released. Check (NO) contacts).

59

Not used.

Valve Stem Inputs Not Configured

5A

T

Main valve stem input is present but not configured. (6.17)

5B Alt

T

Main valve stem input is present but not configured. (6.17)

5C

T

Auxiliary valve stem input is present but not configured. (6.17)

5D Alt

T

Auxiliary valve stem input is present but not configured. (6.17)

5E

T

Dump valve stem input is present but no configured. (6.4, 6.9)

5F Alt

T

Dump valve stem input is present but no cinfigured. (6.4, 6.9)

Downstroke Fault

60

L

RUN button in station 1 released too late in the downstroke.(5.3,5.6,6.13)

61

L

RUN button in station 1 released too late in the downstroke.(5.3,5.6,6.13)

62

L

RUN button in station 1 released too late in the downstroke.(5.3,5.6,6.13)

Advertising