Voting Processor Firmware

Chapter 5

5Ć11

Figure 5.6

Operational Sequence for First Downstroke in Continuous Mode

First Downstroke.

From figure 5.5

Has an operator released a

RUN button, or has a barrier

guard opened?

Both voting processors

deĆenergize their solenoid triacs

to stop the shaft. A stop

condition mesage is displayed.

Did the shaft coast into the

nearĆbottom zone while

braking?

CAUTION: Releasing a RUN button

late in the downstroke can damage

the press.

NOTE: Releasing a RUN button during the first downstroke stops the press. If the shaft has

not entered the near bottom zone, operators can resume the downstroke within 5 seconds of

releasing a RUN button. After 5 seconds, operators must restart continuous mode by means

of the arming sequence.

12265

Yes

Both voting processors

energized their solenoid triacs

for the first downstroke

Has the shaft reached the

nearĆbottom position?

Go to First Upstroke.

Figure 5.7

Yes

No

No

No

Have 5 seconds elapsed since

the solenoid triacs were

deĆenergized?

Have all operators released all

RUN buttons?

Has each operator pressed his

RUN buttons simultaneously,

and within 5 seconds for all

stations?

No

Yes

No

No

Go to Figure 5.5

Select Continuous Mode

Select inch mode and position the

shaft near the top.

Stop Condition

From figure 5.7

Yes

Yes

Yes