Figure 5.3

Operational Sequence for Downstroke in Single Mode

Select single mode

Is the shaft near the top?

Have all operators released all

RUN buttons?

Has each operator pressed his

RUN buttons simultaneously,

and within 5 seconds for all

stations?

Both voting processors

energize their solenoid triacs to

actuate the clutch for the

downstroke

Has an operator released a

RUN button?

Select inch mode and position the

shaft near the top.

NOTE: Releasing a RUN button during the downstroke stops the press. If the shaft does

not reach the nearĆbottom zone, operators may resume the downstroke. If the shaft

reaches the nearĆbottom zone, an operator must inch the press back to the nearĆtop

position.

12262

No

Yes

Yes

No

Is the shaft past the near

bottom zone?

Start upstroke.

Go to figure 5.4

Both voting processors

deĆenergize their solenoid

triacs to stop the shaft. A stop

condition message is

displayed.

Yes

Did the shaft coast into the

near bottom zone while

breaking?

Have all operators released all

RUN buttons?

Has each operator pressed his

RUN buttons simultaneously,

and within 5 seconds for all

stations?

CAUTION: Releasing a RUN

button late in the downstroke

can damage the press

No

No

Yes

No

Yes

No

Yes

Yes

Start onĆtheĆhop

downstroke.

From figure 5.4

No

Yes

Main Motor Forward

Yes