Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 122

Advertising
background image

Troubleshooting

Chapter 7

7Ć38

Diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding

data table word using the industrial terminal.

Use this table in conjunction with figure 7.1 and figure references shown in parentheses.

Type of Message

N = NonĆlatched

L = Latched

T = Trip Condition

Code

P = at PowerĆup

Alt = Alternate chassis

Ethr = Either chassis

Top = Top chassis

Bot = Bottom chassis

Binary

Hex

Type

Code

Diagnostic Message (figure References)

Other Cam Limit Switch Faults

(Figures 5.1, 6.11)

1010 1000

A8

N

P

Cam switches cannot determine shaft position. Inch to top.

1010 1001

A9

N

P

All cam switches are open.

1010 1010

AA

L

Cam switches cannot determine shaft position. Inch to top.

General Faults

1010 1011

AB

N

Not used.

1010 1100

AC

L

Crowbar test input is ON. Check wiring of crowbar testt circuit

1010 1101

AD

N

Awaiting turn off of crowbar relay test.

1010 1110

AE

N

Awaiting turn off of crowbar relay test.

1010 1111

AF

N

Awaiting solenoid power.

Configuration Error

1011 0000

B0

N

Alt

Configuration error in alternate module. Configure it correctly or match inputs to your

configuration.

1011 0001

B1

N

Turn off backplane switch 1.

1011 0010

B2

N

Stations 3 and 4 configuration bitr and backplane switch mismatched

1011 0011

B3

N

Motion detector configuration bit and backplan switch mismatched.

1011 0100

B4

N

Valve stem switch configuration bit and backplance switch mismatched.

1011 0101

B5

N

Air pressure switch configuration bit and backplane switch mismatched.

1011 0110

B6

N

Ungrounded/grounded AC power configuration bit and backplane switch mismatched.

1011 0111

B7

N

OnĆtheĆhop configuration bit and backplane switch mismatched.

1011 1000

B8

N

StrokeĆandĆaĆhalf configuration bit and backplane switch mismatched.

1011 1001

B9

N

Dump valve configuration bit disagrees with corresponding I/O modules in chassis.

1011 1010

BA

N

An I/O input module is missing.