Field Wiring Arm Connections

Chapter 6

6Ć14

Figure 6.3

Connections for Main and Auxiliary Valve Solenoids, MOV Surge Suppression, Crowbar and

Seal Relays (Ungrounded AC Power)

LRB

LRA

LRB

LRA

3L1

Main Valve

Solenoids

A B

A

B

3L2

2L2

2L2

Chassis A

1

2

3L2

Module Group 2

Slot 1

Module Group 3

Slot 0

NOTES: Use this wiring with figure 6.1 for ungrounded AC power.

LRA and LRB load resistors for triac feedback are 2K ohm, 15 watt resistors
Each solenoid or relay coil should draw at least 60mA.
Connect one MOV between 3L1 and 3L2 for electrical noise suppression.
Connect one MOV to the 3L1 side of each solenoid load and to 3L2 for electrica

l

noise suppression.

If solenoid are not used, replace with 2K ohm, 15 watt resistors.

1
2

17882

B

B

A

A

Seal Relay

Crowbar Relay

Auxiliary

Valve

Solenoids

4

2

2

3

3
4

3L1

3L2

Crowbar Relay

Seal Relay

A

0
1
2
3
4
5
6
7

A

0
1
2
3
4
5
6
7

1
2
3
4
5
6
7
8
9

10
11
12

1
2
3
4
5
6
7
8
9

10
11
12

2

5

4

5

Chassis B

B

B

Chassis A

Chassis B

1771ĆIA

1771ĆOD