Figure 7.1

Module Indicators for Chassis A or B

12292

ACTIVE

(green)

CBM

FAULT

(red)

I/O RACK

FAULT

(red)

Output status

indicators are red.

On = output

Blown fuse

indicators are clear.

On = blown fuse

Input Module Indicators

Input status indicators are clear. On = input

One indicator per terminal.

1771-PM Module

1771-IA Modules

1771-OD Module

Refer to tables 7.A and 7.B

Output Module Indicators

PM Module Indicators

Table 7.A

ACTIVE Indicator

If the ACTIVE indicator is blinking, identify the problem by the number of blinks. There are 2 sets of blinks:

first set of blinks

short pause

second set of blinks

long pause

repeat continuously

Number of Blinks

1st Set

2nd Set

Problem

Correction

1

3

Faulty RAM

Replace 1771ĆPM module

1

4

Faulty PROM

Replace 1771ĆPM module

2

1

Illegal rack address

Set the 1771ĆPM module switches as detailed in chapter 3

2

3

The 1771ĆPM modules contain different firmware

Install 1771ĆPM modules with identical revision codes

3

2

Missing a 1771ĆPM module at power up

Install and fully seat both 1771ĆPM modules

3

4

Illegal interrupt

Cycle power Replace 1771ĆPM module

4

1

Firmware fault

Replace 1771ĆPM module

4

3

Lost communications between 1771ĆPM modules,

or watchdog timed out

Check connections between 1771ĆPM modules or

Replace 1771ĆPM module