Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 119

Advertising
background image

Troubleshooting

Chapter 7

7Ć35

diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding

data table word using the industrial terminal.

Use this table in conjunction with figure 7.1 and figure references shown in parentheses.

Type of Message

N = NonĆlatched

L = Latched

T = Trip Condition

Code

P = at PowerĆup

Alt = Alternate chassis

Ethr = Either chassis

Top = Top chassis

Bot = Bottom chassis

Binary

Diagnostic Message (figure References)

Code

Type

Hex

1110 0110

E6

T

Aux. valve stem signal off when triacs are on.

1

1110 0111

E7

T

Alt

Aux. valve stem signal off when triacs are on.

1

1110 1000

E8

T

Dump valve stem signal off when traics are on.

1

1110 1001

E9

T

Alt

Dump valve stem signal off when traics are on.

1

1110 1010

EA

T

Main valve stem signal remains on after triacs turn off.

1

1110 1011

EB

T

Alt

Main valve stem signal remains on after triacs turn off.

1

1110 1100

EC

T

Aux. valve stem signal remain on after triacs turn off.

1

1110 1101

ED

T

Alt

Aux. valve stem signal remain on after triacs turn off.

1

1110 1110

EE

T

Dump valve stem signal remains on after traics tuirn off.

1

1110 1111

EF

T

Alt

Dump valve stem signal remains on after traics tuirn off.

1

Hardware or Cable Fault

1111 0000

F0

T

Alt

Chassis power tripped or chassis restarted. (6.1, 6.6)

1111 0001

F1

L

Lost communications between 1771ĆPM modules. Reset latched message, check cables, or

cycle power. (3.3)

1111 0010

F2

L

Lost communications with PC. Reset latched mesage, check cables, or cycle power. (3.3)

1111 0011

F3

L

Alt

Lost communications with PC. Reset latched mesage, check cables, or cycle power. (3.3)

1111 0100

F4

N

Lost communications between 1771ĆPM modules.

2

1111 0101

F5

N

Hardware fault in 1771ĆPM module. Replace it.

1111 0110

F6

N

Turn off backplane switch 1. (3.4)

1111 0111

F7

N

Hardware fault in 1771ĆPM module.

2

1111 1000

F8

N

Not used

1111 1001

F9

N

Hardware fault in 1771ĆPM module.

2

1111 1010

FA

N

1771ĆPM modules must be same revision.

1111 1011

FB

N

Hardware fault in 1771ĆPM module. Replace it.

Advertising