Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 109

Advertising
background image

Troubleshooting

Chapter 7

7Ć25

Diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by

displaying the corresponding data table word using the industrial terminal.

Use this table in conjunction with figure 7.1 and figure references shown in parentheses.

Type of Message

N = NonĆlatched

L = Latched

T = Trip

Condition

Code

P = at PowerĆup

Alt = Alternate chassis

Ethr = Either chassis

Top = Top chassis

Bot = Bottom chassis

Hex

Code

Diagnostic Message (figure References)

Type

13

N

RUN button not released. Check (NC) contacts.

14Alt

N

RUN button not released. Check (NC) contacts.

15

P

N

Make left and right active connections identical.

16

P

N

(NC) RUN button is open. Check button or wiring.

17

P

N

(NO) RUN button is shorted. Check button or wiring.

18

T

Active input changed from closed to open. Check wiring.

19 Alt

T

Active input changed from closed to open. Check wiring.

1A

T

(NC) RUN button bypass is open. Check wiring

1B Alt

T

(NC) RUN button bypass is open. Check wiring

1C

T

(NO) RUN button bypass is open. Check wiring

1D Alt

T

(NO) RUN button bypass is open. Check wiring

1E

Not Used.

1F

Not Used

Station 2

(Figure 6.14)

20

N

Check RUN button signals. Make station active or bypassed.

21

N

RUN button not released. Check (NO) contacts.

22 Alt

N

RUN button not released. Check (NO) contacts.

23

N

RUN button not released. Check (NC) contacts.

24 Alt

N

RUN button not released. Check (NC) contacts.

25 P

N

Make left and right active connections identical.

26

P

N

(NC) RUN button is open. Check button or wiring.

27

P

N

(NO) RUN button is shorted. Check button or wiring.

Advertising