Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 118

Advertising
background image

Troubleshooting

Chapter 7

7Ć34

diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding

data table word using the industrial terminal.

Use this table in conjunction with figure 7.1 and figure references shown in parentheses.

Type of Message

N = NonĆlatched

L = Latched

T = Trip Condition

Code

P = at PowerĆup

Alt = Alternate chassis

Ethr = Either chassis

Top = Top chassis

Bot = Bottom chassis

Binary

Diagnostic Message (figure References)

Code

Type

Hex

1101 0001

D1

T

Top

Triac 7 off when commanded on.

1

1101 0010

D2

T

Ethr

Triac 0 off when commanded on.

1

1101 0011

D3

T

Ethr

Triac 1 off when commanded on.

1

1101 0100

D4

T

Ethr

Triac 2 off when commanded on.

1

1101 0101

D5

T

Ethr

Triac 3 off when commanded on.

1

1101 0110

D6

T

Ethr

Triac 6 off when commanded on.

1

1101 0111

D7

T

Ethr

Triac 7 off when commanded on.

1

1101 1000

D8

T

Top

Triac 0 remains on after turned off.

1

1101 1001

D9

T

Top

Triac 1 remains on after turned off.

1

1101 1010

DA

T

Top

Triac 2 remains on after turned off.

1

1101 1011

DB

T

Top

Triac 3 remains on after turned off.

1

1101 1100

DC

T

Top

Triac 6 remains on after turned off.

1

1101 1101

DD

T

Top

Triac 7 remains on after turned off.

1

Fault in Valve Stem Feedback

1101 1110

DE

T

Main valve stem signal on when triacs are off.

1

1101 1111

DF

T

Alt

Main valve stem signal on when triacs are off.

1

1110 0000

E0

T

Aux. valve stem signal on when triacs are off.

1

1110 0001

E1

T

Alt

Aux. valve stem signal on when triacs are off.

1

1110 0010

E2

T

Dump valve stem signal on when traics are off.

1

1110 0011

E3

T

Alt

Dump valve stem signal on when traics are off.

1

1110 0100

E4

T

Main valve stem signal off when triacs are on.

1

1110 0101

E5

T

Alt

Main valve stem signal off when triacs are on.

1