Figure 5.7, From figure 5.7, Voting processor firmware chapter 5 – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 51

Advertising
background image

Voting Processor Firmware

Chapter 5

5Ć12

Figure 5.7

Operational Sequence for First Upstroke and Second Downstroke in Continuous Mode

First Upstroke.

From figure 5.6

Both voting processors continue

actuating the clutch for the first

upstroke

Has an operator released a RUN

button, or has the barrier guard

opened?

Is the shaft in the nearĆtop

position?

Select inch mode and position the

shaft near the top.

NOTE: HalfĆstroke or StrokeĆandĆaĆhalf requires all operators to hold all RUN buttons until the first

or second downstroke is completed. Releasing a RUN button during the (first) upstroke requires

restarting continuous mode at the arming sequence. Releasing a RUN button in the first or second

downstroke requires restarting as if an operator had stopped the press in the first downstroke.

12266

Yes

Did the shaft stop in the

nearĆbottom position?

Has 1/2 or 1 1/2 stroke been

configured?

Yes

No

Both voting processors continue

actuating the clutch for the

second downstroke

Has an operator released a RUN

button, or has a barrier guard

opened?

No

Yes

Go to Figure 5.5

Select Continuous Mode

No

Yes

No

Go to

Continuous

Stroking

Figure 5.8

Go to

Stop Condition

Figure 5.6

Yes

No

Both voting processors

de-energized their solenoid

triacs to stop the press.

Advertising