Troubleshooting

Chapter 7

7Ć36

diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding

data table word using the industrial terminal.

Use this table in conjunction with figure 7.1 and figure references shown in parentheses.

Type of Message

N = NonĆlatched

L = Latched

T = Trip Condition

Code

P = at PowerĆup

Alt = Alternate chassis

Ethr = Either chassis

Top = Top chassis

Bot = Bottom chassis

Binary

Diagnostic Message (figure References)

Code

Type

Hex

1111 1100

FC

N

Backplane error. Replace chassis.

2

1111 1101

FD

N

Hardware fault in 1771ĆPM module.

2

1111 1110

FE

N

Hardware fault in 1771ĆPM module.

2

1111 1111

FF

N

PowerĆup other 1771ĆPM module.

MicroĆinch Diagnostic Codes

(Examine module group 3, slot 1, bit 2, chassis A and B for MSB)

1 0101 1010

15A

T

MicroĆinch valve stem input is present though not configured.

1 0101 1011

15B

T

Alt

MicroĆinch valve stem input is present though not configured.

1 1011 1100

1BC

T

MicroĆinch clutch pressure input is present though not configured.

1 1011 1101

1BD

T

MicroĆinch clutch pressure input is present when triacs are off.

1 1011 1110

1BE

T

MicroĆinch clutch pressure input is off when triacs are on.

1 1011 1111

1BF

T

MicroĆinch clutch pressure input remains on after triacs turn off.

1 1100 0000

1C0

T

Ethr

Triac 8 is on when commanded off.

1 1100 0001

1C1

T

Ethr

Triac 9 is on when commanded off.

1 1100 0110

1C6

T

Bot

Triac 8 is on when commanded off.

1 1100 0111

1C7

T

Bot

Triac 9 is on when commanded off.

1 1100 1100

1CC

T

Top

Triac 8 is off when commanded on.

1 1100 1101

1CD

T

Top

Triac 9 is off when commanded on.

1 1101 0010

1D2

T

Ethr

Triac 8 is off when commanded on.

1 1101 0011

1D3

T

Ethr

Triac is off when commanded on.