Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 95

Advertising
background image

Troubleshooting

Chapter 7

7Ć11

ReĆstarting the Press

You re-start the press with this procedure:

1.

When the “OD” message is displayed, press ESTOP to drop the seal
relays.

Message code “50” is displayed (swingarm power dropout)

2.

Press the START button.

3.

Press the RESET LATCHED MSG button.

4.

Select INCH mode if not already selected.

5.

Inch the press to the near-top position.

Types of OD" Diagnostic Message Codes

The “OD” diagnostic message code accompanies the following type of
diagnostic messages.

Type of Message

Hex Code

Downstroke

066 Ć 067

Upstroke

068 Ć 069

Brake or Motion Detector

072 Ć 079, 07A

Cam Limit Switch

Near Top Position

Transition to Downstroke

Downstroke

Transition to Near Bottom Zone

Near Bottom Zone

Transition to Upstroke

Upstroke

Transition to Near Top Position

080 Ć 085

086 Ć 089

08A Ć 08F

090 Ć 093

094 Ć 099

09A Ć 09D

09E Ć 09F, 0A0 Ć 0A3

0A4 Ć 0A7

Hardware or Cable

0F1 Ć 0F3

Advertising