Troubleshooting chapter 7 – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 89

Advertising
background image

Troubleshooting

Chapter 7

7Ć5

3. Determine the input or device causing the fault from the

section/sub-section heading in Table 7.D where the fault code was
tabulated and from other figures or tables referred to.

4. Interpret the messages. Was this output supposed to be on? Was that

device supposed to be off?

Figure 7.3

Troubleshooting Flowchart for Diagnostic diagnostic message codes

Press will not run.

Is a diagnostic message

displayed?

See Table 7.C

Does the problem relate to an

input switch or connection?

Go to figure 7.2

Yes

No

No

12291

Does the problem relate to a

solenoid or its triac?

No

Take action according to Table

7.C

Is a blown fuse indicator on for

any 1771ĆOD module? (See

Figure 7.1)

Replace the fuse.

No

Replace the 1771ĆOD module or

the solenoid. Check solenoid

wiring.

Yes

Yes

Does the status indicator for the

input to the 1771ĆIA module

respond correctly? (See Figure

7.1)

Yes

Replace the 1771ĆIA module.

No

Replace the input switch or

check its wiring.

Warning: To guard against injury to personnel, open and lock the main power disconnect before adjusting, replacing, or repairing any

mechanical or electrical component in your press system. This consists of the press, clutchbrake, controller, and all associated wiring and

control panels.