Bit Monitoring Address

Appendix A

AĆ5

Module Group 3

Slot 0, 1771-OD, Figure 6.3 or 6.7

Addresses

Term.

Function

PLC-2/30

Chassis

A B

PLC-3

Chassis

A B

1 & 2

Triac 0 for Main Solenoid A

1a3/00

1b3/00

10ab3/00

10ac3/00

3 & 4

Triac 1 for Main Solenoid B

1a3/01

1b3/01

10ab3/01

10ac3/01

5 & 6

Triac 2 for Auxiliary Solenoid A

1a3/02

1b3/02

10ab3/02

10ac3/02

7 & 8

Triac 3 for Auxiliary Solenoid B

1a3/03

1b3/03

10ab3/03

10ac3/03

9 & 10

Triac 4 for Crowbar Relay A

Relay B

1a3/04

1b3/04

10ab3/04

10ac3/04

11 & 12

Triac 5 for Seal Relay A

Relay B

1a3/05

1b3/05

10ab3/05

10ac3/05

Slot 1, 1771-OA, Figure 6.14

Addresses

Term.

Function

PLC-2/30

Chassis

A B

PLC-3

Chassis

A B

0

BRAKE FAULT Indicator

1a3/10

10ab3/10

1

RUN WINDOW Indicator

1a3/11

10ab3/11

2

MICRO-INCH Indicator

1a3/12

1b3/12

10ab3/12

10ac3/1

3-7

Not Used