Bit Monitoring Address
Appendix A
AĆ5
Module Group 3
Slot 0, 1771-OD, Figure 6.3 or 6.7
Addresses
Term.
Function
PLC-2/30
Chassis
A B
PLC-3
Chassis
A B
1 & 2
Triac 0 for Main Solenoid A
1a3/00
1b3/00
10ab3/00
10ac3/00
3 & 4
Triac 1 for Main Solenoid B
1a3/01
1b3/01
10ab3/01
10ac3/01
5 & 6
Triac 2 for Auxiliary Solenoid A
1a3/02
1b3/02
10ab3/02
10ac3/02
7 & 8
Triac 3 for Auxiliary Solenoid B
1a3/03
1b3/03
10ab3/03
10ac3/03
9 & 10
Triac 4 for Crowbar Relay A
Relay B
1a3/04
1b3/04
10ab3/04
10ac3/04
11 & 12
Triac 5 for Seal Relay A
Relay B
1a3/05
1b3/05
10ab3/05
10ac3/05
Addresses
Term.
Function
PLC-2/30
Chassis
A B
PLC-3
Chassis
A B
0
BRAKE FAULT Indicator
1a3/10
10ab3/10
1
RUN WINDOW Indicator
1a3/11
10ab3/11
2
MICRO-INCH Indicator
1a3/12
1b3/12
10ab3/12
10ac3/1
3-7
Not Used