Chapter 7

7Ć14

Table 7.C

Diagnostic Message Codes Associated with the "0D" Message Code

MISCELLANEOUS MESSAGES

HEX

CODE

TYPE

PROBLEM

CORRECTIVE ACTION

01

N

IMPROPER MODE SELECTION

The PM module expects to see one of the allowable press

modes (off, inch, microĆinch, single, continuous, within 0.1 sec's

after swingarm power is sealed in, and will only allow one mode

at any given time.

Check selector switch wiring in figure 6.10 and operation.

Check wiring to swingĆarm. Check I/O module for correct

operation.

02

N

ALL STATIONS BYPASSED

In the single stroke or continuous mode, the PM will not allow the

press to cycle if all operator run stations are bypassed. At least

one station must be present. Inch and microĆinch modes will

operate with all run stations bypassed.

Check station wiring in figures 6.11 and 6.12. Check

swingĆarm wiring and I/O module for proper operation.

03

N

SHAFT NOT AT TOP. CAN NOT ENTER SINGLE OR

CONTINUOUS MODE

The PM is selected to go into the single or continuous mode, but

the cam switches, which indicate shaft position, are telling the

PM that the press is not at the top.

Check for proper cam settings in figure 5.1. Check for

proper cam wiring in figure 6.9. Inch press to the top

position.

04

N

AWAITING RELEASE OF ALL RUN BUTTONS FOR ENTERING

SINGLE OR CONTINUOUS MODES

Release all run buttons. Check for proper operation of all

buttons. Check button wiring in figures 6.11 and 6.12.

05

N/L

MAIN MOTOR FORWARD CONTACT DROPOUT OR ABSENT

The main motor forward input needs to be on in order to enter

single or continuous modes. Once in single or continuous mode,

the press will stop if that input goes off.

Check feedback contact and wiring in figure 6.10. Check

swingĆarm wiring and I/O module for proper operation.

06

N

ACAM OPEN, PREVENTING ENTRY INTO SINGLE OR

CONTINUOUS MODE.

Check wiring of ACAM in figure 6.9 and check ACAM

position in figure 5.1.

07

N

AWAITING RELEASE OF ALL STOPĆONĆTOP BUTTONS FOR

ENTERING CONTINUOUS MODE.

You must release STOPĆONĆTOP buttons of all active stations

before the PM can switch to another mode of press operation.

Check RUN button wiring figures 6.11 and 6.12.

08

N

AWAITING RELEASE OF ARM CONTINUOUS BUTTON FOR

ENTERING CONTINUOUS MODE.

You must release the ARM CONTINUOUS button and press the

RUN buttons of all active stations before the PM can switch to

continuous mode.

Check ARM CONTINUOUS button wiring figure 6.10.

09

L

BARRIER GUARD DROPOUT OR ABSENT.

Press stops operation.

Check for faulty switch, broken wire, etc. figure 6.10.