Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 117

Advertising
background image

Troubleshooting

Chapter 7

7Ć33

diagnostic message codes are displayed by indicators connected to module group 5, slot 1 (figure 6.18), or by displaying the corresponding

data table word using the industrial terminal.

Use this table in conjunction with figure 7.1 and figure references shown in parentheses.

Type of Message

N = NonĆlatched

L = Latched

T = Trip Condition

Code

P = at PowerĆup

Alt = Alternate chassis

Ethr = Either chassis

Top = Top chassis

Bot = Bottom chassis

Binary

Hex

Type

Code

Diagnostic Message (figure References)

1011 1100

BC

T

Air pressure signal present though air pressure feedback is not configured.

1011 1101

BD

T

Air pressure signal on when triacs are off.

1011 1110

BE

T

Air pressure signal on when triacs are on.

1011 1111

BF

T

Air pressure signal remains after triacs turn off.

Triac Fault

1100 0000

C0

T

Ethr

Triac 0 on when commanded off.

1

1100 0001

C1

T

Ethr

Triac 1 on when commanded off.

1

1100 0010

C2

T

Ethr

Triac 2 on when commanded off.

1

1100 0011

C3

T

Ethr

Triac 3 on when commanded off.

1

1100 0100

C4

T

Ethr

Triac 6 on when commanded off.

1

1100 0101

C5

T

Ehtr

Triac 7 on when commanded off.

1

1100 0110

C6

T

Bot

Triac 0 on when commanded off.

1

1100 0111

C7

T

Bot

Triac 1 on when commanded off.

1

1100 1000

C8

T

Bot

Triac 2 on when commanded off.

1

1100 1001

C9

T

Bot

Triac 3 on when commanded off.

1

1100 1010

CA

T

Bot

Triac 6 on when commanded off.

1

1100 1011

CB

T

Bot

Triac 7 on when commanded off.

1

1100 1100

CC

T

Top

Triac 0 off when commanded off.

1

1100 1101

CD

T

Top

Triac 1 off when commanded off.

1

1100 1110

CE

T

Top

Triac 2 off when commanded off.

1

1100 1111

CF

T

Top

Triac 3 off when commanded off.

1

1101 0000

D0

T

Top

Triac 6 off when commanded on.

1