Multiple clutch/brake controllers, Panel switches and operator stations – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 15

Advertising
background image

Clutch/Brake Controller Hardware

Chapter 3

3Ć6

Although this manual describes a single clutch/brake controller, you may
connect your PLC to multiple controllers, each controlling a separate
press. Each clutch/brake controller uses two remote I/O racks for chassis
A and B. For example, since a PLC-3 controller can support as many as
32 I/O racks, you may connect it to as many as 15 clutch/brake controllers
with two additional I/O racks for modules in chassis C.

You can operate your press using up to four operator stations and an
optional control panel. Installations vary according to the type of
mechanical press and its application requirements. The number of
stations, control switches contained in each, and the control panel could
be as follows:

Assembly

Control Switches

Notes

Control Panel and/or Station 1 Mode select

Arm continuous

StopĆonĆtop

L/R Inch

Press enable

Reset latched messages

Lamp test

L/R Run

EĆStop

1

1

1 and/or 3

2

3

3

3

2

2

Stations 2 thru 4

L/R Run

Stop On Top

EĆStop

2

2 and/or 3

2

1 Connect these switches to input modules in chassis A and B (Figure 6.10).

2 Connect these switches to input modules in chassis A and B (Figures 6.11 thru

6.12).

3 These switches are inputs for command rungs (Figures 4.6 thru 4.8). Connect

these switches to input modules in remote I/O chassis C (Figure 6.15).

Multiple Clutch/Brake

Controllers

Panel Switches and Operator

Stations

Advertising