Figure 6.9, Field wiring arm connections chapter 6 – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 73

Advertising
background image

Field Wiring Arm Connections

Chapter 6

6Ć21

Figure 6.9

Connections for Cam Limit Switch Assemblies

2L2

Run-On (RCAM)

Anti-Repeat (ACAM)

2L1

Chassis A

Cam Limit Switch

Assembly A

1771-IA

Slot 1

2L1

Chassis B

Cam Limit Switch

Assembly B

12278

A

0

1

2

3

4

5

6

7

A

0

1

2

3

4

5

6

7

2L2

[1]

[1]

470 ohm 50 watt 1%, or 500 ohm 5% on seperate terminal strip.

+-

+-

Module Group 1

B

B

[1]

TopĆstopĆcheck (TCAM)

Run-On (RCAM)

Anti-Repeat (ACAM)

TopĆstopĆcheck (TCAM)