Figure 6.7, Figure 6.7 and, Figure 6.7 f – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual

Page 70: Figure 6.7 also shows connections for, Field wiring arm connections chapter 6

Advertising
background image

Field Wiring Arm Connections

Chapter 6

6Ć18

Figure 6.7

Connections for Main and Auxiliary Valve Solenoids, Crowbar and Seal Relays, and MOV

Surge Suppression (Grounded AC Power)

LRB

LRA

LRB

LRA

3L1

Main

Valve

Solenoids

A B

3L2

2L2

2L2

Chassis A

1

3

3L2

Module Group 2

Slot 1

Module Group 3

Slot 0

NOTES: Use this wiring with figure 6.5 for grounded AC power.

LRA and LRB load resistors for triac feedback are 2K ohm, 15 watt resistors
If auxiliary solenoids are not used, replace with 2K ohm, 15 watt resistors.
Each solenoid or relay coil should draw at least 60mA.
Connect one MOV between 3L1 and 3L2 for electrical noise suppression.
Connect one MOV to the 3L1 side of each solenoid load and to 3L2 for electrical noise suppression.