Canon REALiS X600 User Manual

Page 10

Advertising
background image

User Command Specifications

2. Communication Specifications

Transmission is recognized when delimiter is received.
Even if a maximum transmission length is received, the entire received transmission will be lost unless a delimiter is received.

The <Parameter value> is defined as shown below.

<Parameter value>:=<Value 1><Value 2> .. <Value n>
<Value> := <Numerical value> | <ID> | “<Character string>”

:= [<Sign>] <Decimal character string (Min. 1 character to Max. 5 characters)>

:= 1 or more ASCII characters (20h to 7Fh)
:= 0 or more ASCII characters (20h to 7Fh)

The connection diagram (example) for the cable connecting the PC and projector is shown below.

The range of valid values is -32768 to 32767.

Cable

Other

<ID>

Transmission

recognition

Parameter

value

Definition

<Numerical value>

<Character string>

① ②

③ ④

⑥ ⑦ ⑧

1

5

6

9

D-SUB 9pin FEMALE

PC

PJ

MINI DIN 8pin MALE

SHIELD

SHIELD

1 CD (DCD)

2 RD (RXD)

3 SD (TXD)

4 ER (DTR)

5 SG (GND)

6 DR (DSR)

7 RS (RTS)

8 CS (CTS)

9 CI (RI)

3 SD (TXD)

5 RD (RXD)

4 SG (GND)

2 NC

1 RS(RTS)

6 NC

7 NC

8 NC

PC

PJ

接続例 1

SHIELD

SHIELD

1 CD (DCD)

2 RD (RXD)

3 SD (TXD)

4 ER (DTR)

5 SG (GND)

6 DR (DSR)

7 RS (RTS)

8 CS (CTS)

9 CI (RI)

3 SD (TXD)

5 RD (RXD)

4 SG (GND)

PC

PJ

接続例 2

PCで「CS」、「DR」を使用する場合の自己折返し結線例。

SHIELD

SHIELD

1 CD (DCD)

2 RD (RXD)

3 SD (TXD)

4 ER (DTR)

5 SG (GND)

6 DR (DSR)

7 RS (RTS)

8 CS (CTS)

9 CI (RI)

3 SD (TXD)

5 RD (RXD)

4 SG (GND)

PC

PJ

接続例 3

最小限の結線例です。

キヤノン標準ケーブルの結線です。

PC側の「RS」は使用しないでください!

Sample 1

Sample 3

Sample 2

Example of self-loopback connections when the
"CS" and "DR" pins are used in the connector of
the PC.

Canon's standard cable is used for
these connections.
Do not use the "RS" pin in the
connector of the PC!

Example of minimally required connections.

PAGE 5