User Command Specifications

10. Error List

1 10. Error List

(1) (2) (3) (4)

2

e

○ ○ ○ ○

Send the correct command.

4

e

○ ○ ○ ○

Send in the correct command format.

8

e

○ ○ ○ ○

i

○ ○ ○

i

○ ○ ○

e

○ ○ ○ ○

e

○ ○ ○

e

○ ○ ○

e

○ ○ ○

e

○ ○ ○ ○

i

○ ○ ○ ○

i

○ ○ ○ ○

i

○ ○ ○

i

○ ○ ○

16

e

○ ○ ○ ○

e

○ ○ ○ ○

e

○ ○ ○

18

i

○ ○ ○

The error code is expressed as a four-digit hexadecimal character string. ‘X’ is a number from ‘0’ to ‘9’ or letter from ‘A’ to ‘F’.

Given below is the correspondence between the numbers (1) to (4) in the "Errors supported by model" column and the models concerned.

(1) SX50
(2) SX6
(3) SX60
(4) X600

The zoom lens is now being driven.

Wait until the zoom lens drive stops.

10

BUSY (FOCUS)

The focus lens is now being driven.

17

BUSY (INTERNAL_PROCESS)

Heavy processing is in progress.

INVALID_VALUE

Numerical parameters are invalid or
outside the range.

1003

IP conversion cannot be performed.

15

BUSY (FOCUS)

○ ○ ○ ○

Command is invalid (undefined).

Communication sequence error

Wait until the response is received to send
the command.

Remedy

0002

0801
0802

INVALID_COMMAND

000B

JOB_TIMEOUT

0004

INVALID_FORMAT

F001

BUSY (ZOOM)

USER_COMMAND_VERSION_IS_UPDATED

Change to the correct resolution of the
input signal.

The input signal resolution is not correct.

1002 e NO_LOGO_CAPTURED

Change to the correct input signal.

203X e INVALID_RESOLUTION (***)

Register the user image.

INVALID_PARAMETER

e

000A

7

E0XX

12

e

9

11

F005

F002
F004

6

i

BUSY

Wait until the processing is completed.

Resend the command.

There is no signal input.

Resend the command.

Signal setting (detection) is in progress.

Input the signal.

A communication protocol violation
occurred in the projector.

Eliminate the cause of the error, and
resend the command.

An error occurred in AUTOSETEXE=SCRN.

Change the input signal.

Use the TERMINAL command to set the
terminal to input, and then select the input
again.

The focus lens is now being driven.

The input cannot be selected since the
terminal is set to output.

Processing cannot be executed since the
user image is not registered.

Wait until the focus lens drive stops.

The zoom lens is now being driven.

Wait until the zoom lens drive stops.

Use the RANGE command to obtain the
parameter range, and then use a
parameter within the range.

Switch the mode using the REMOTE or
LOCAL command.

An error occurred in AUTOSETEXE=VKS.

Mode switching or processing inside the
projector is underway.

Wait until the power supply state changes
to “ON”, “OFF”, or “PMM”.

Resend the command.
Use GET COMVER to obtain the latest
user command version.

The user command version is being updated.

The command format is incorrect.

SX50 internal processing has timed out.

Wait until the focus lens drive stops.

1 0001 e BAD_SEQUENCE

3 0003 e

1006

13

e

1005

1001

e

w

NOW_BLANK

AUTOSETEXE=FOCUS or SCRN cannot
be executed since BLANK is ON.

After setting BLANK to ON, resend the
command.

NO_SIGNAL

BUSY (NOW_SETTING)

COMMUNICATION_ERROR

10. Error List

Error

Item

Code

TYPE

Error character strings

Errors

supported by

model

The designated command cannot be
executed in this mode.

INVALID_MODE

○ ○ ○ ○

○ ○ ○

○ ○ ○

○ ○ ○ ○

○ ○ ○

○ ○

SYSTEM (SCREEN_COLOR)

SYSTEM (UNKNOWN)

An internal error occurred.

SYSTEM (FOCUS)

An error occurred in AUTOSETEXE=FOCUS.

SYSTEM (AUTO_KEYSTONE)

INPUT_NOT_FOUND

The input was not switched since no input signal
was found with AUTOSETEXE=INPUT.

INVALID_SOURCE (****)

e

200X

○ ○

There is no action to be taken since the
status has been notified.

Use the POWER ON command to turn on
the power.

Power is not being supplied.

Use the correct parameter(s).

The parameter (type) is invalid
(undefined).This includes the case when
the number of parameters is incorrect.

This cannot be executed with the current
input source.
The current input source is indicated in
parentheses.

Change the input source.

NOT_POWER_SUPPLIED

5 0005 e

e

201X

14

2010

INVALID_SIGNAL (****)

This cannot be executed with the current
input signal.
The current input signal is indicated in
parentheses.

BUSY (ZOOM)

Preparing to switch to power management
standby.

BUSY
(POWER_MANAGEMENT_READY)

i

IP_NOT_AVAILABLE

TERMINAL_OUT

e

Set DPON to ON when PMM is not OFF.

DPON cannot be set to ON when PMM is
OFF.

POWER_MANEGEMENT_OFF

Errors with the newer item numbers have higher priority. (When there is more than one error, the highest level error is returned. However, error priority
is the same within the same item number.)

1004

Set DPON to OFF.

PMM cannot be set to OFF when DPON is
ON.

DIRECT_POWER_ON

PAGE 177