Get comver – Canon REALiS X600 User Manual

Page 133

Advertising
background image

User Command Specifications

9.Details of command GET COMVER

1

GET COMVER

GET COMVER

GETCOMVER
?
COMVER

g:COMVER="<User command versionCharacter string>"

<User command version> := 99.9999

For all other responses, refer to "Error List."

-1 This inquiry can be executed in any status provided that AC power is supplied to the projector.

-2

> GET COMVER or ? COMVER
< g:COMVER="01.0000"

* Commands are indicated by ">", and responses are indicated by "<".

Supported Command States

OFF ON

PM

* If a command cannot be supported, 'INVALID_MODE' is returned as an error response.

* "i:BUSY" may be returned if the power status is being switched.

The user command version consists of a 2-digit number followed by a 4-digit number. Question
marks may appear in place of the numerals if the firmware has not been upgraded correctly.
(Example "??:????")

X600

SX60

SX6

×

SX50

S-Video D-Video SCART

None

Mode

Remote

Local

Remarks

Model

Power

Input

D-RGB A-RGB1 A-RGB2 Comp

Video

Control Setting

Description

Response

This inquires about the user command version of the projector.

Character

string

Reference

For the "SX50," the remote mode must be established.

Commands

Function

Format

User command version inquiry

Mode

X600

01.01**

Commands

supported

Example

SX50

SX6

SX60

01.00**

01.01**

01.01**

PAGE 125

Advertising
This manual is related to the following products: