Examples, Application tag commands – ThingMagic M5e-Compact User Manual

Page 102

Advertising
background image

Application Tag Commands

102

Command Set

Examples

The following example will attempt to write to Reserved Memory to set the Kill
password=0x11112222. It will write this data to a tag matching the following criteria for a
max timeout of 1000 ms.

Memory Bank = User Memory.

Starting Address = bit 32

Select Data = 0x1234

The Reserved Memory bank is not locked so the Access Password is zero

If Option=0x00 or 0x01 is used then the unused

Tag Singulation Fields

must be removed

from the request.

Note

If Option=00, the write tag data is performed without any select criteria
resulting the first tag found being written. In that case there is no way to
determine what tag gets written to unless there is only one tag in the RF
field.

The next example will attempt to write 4 words to User Memory starting at the second
word. It will write this data to a tag matching the following criteria for a max timeout of
1000 ms.

EPC ID= 0x0123456789ABCDEF01234567

The User Memory bank is not locked so the Access Password is zero

FF

17

24

03 E8

03

00

00

00

00

00

00

00

00

00

00

00

00

20

10

12

34

SOH

Lengt

h

OpCode

Time-

out (ms)

Option

Write Address

Write

MemBank

Access Password

Select Address

Select

Data

Length

Select

Data

11

11

22

22

3E

71

Write Data

CRC

FF

21

24

03 E8

01

00

00

00

02

03

00

00

00

00

60

SOH

Lengt

h

OpCode

Time-

out (ms)

Option

Write Address

Write

MemBank

Access Password

Select

Data

Length