Set current region (97h), Set current region, 97h) – ThingMagic M5e-Compact User Manual

Page 160: Set application commands

Advertising
background image

Set Application Commands

160

Command Set

This example sets the GPIO Output #1 to ‘1’ (high). To get the current status of the GPIO
output pins, send the same command, with the length set to 0:

The response looks similar to the Get User GPIO Inputs command:

Set Current Region (97h)

The Set Current Region command sets the current region for use in the reader. The list
of region codes are found in

Region codes

. See

Regional Support

for more information on

regional functionality.

Setting the region performs the following:

1.

Frequency hop table is set to the default for the region.

2.

Any other region specific settings are set (i.e. LBT) to default values unless otherwise

specified. Currently only LBT is configurable for regions supporting it.

The Set Current Region command supports two command syntaxes:

The basic syntax for all regions where only the region code is specified. For example,

to set the region to KR:

The extended syntax allowing the region code plus LBT Enabled (if supported by

Region) to be set. For example, to set the Region to EU3 and Enable LBT:

FF

00

96

1D

99

SOH

Length

OpCode

CRC

FF

02

96

00

00

00

01

29

E0

SOH

Length

OpCode

Status

Output #1

Output #2

CRC

FF

01

97

03

4B

BE

SOH

Length

OpCode

Region

CRC

FF

02

97

08

01

19

FD

SOH

Length

OpCode

Region

LBT Enable

CRC

Advertising
This manual is related to the following products: