Fault_msg_power_too_high – 103h, Cause, Solution – ThingMagic M5e-Compact User Manual

Page 213: Fault_msg_invalid_freq_received - 104h, Fault_msg_invalid_parameter_value - 105h

Advertising
background image

Common Error Messages

Appendix C: Error Messages

213

FAULT_MSG_POWER_TOO_HIGH – 103h

Cause

A message was sent to set the read or write power to a level that is higher than the
current HW supports.

Solution

Check the HW specifications for the supported powers and insure that the level is not
exceeded.

The M5e 1 Watt units support power from 5 dBm to 30 dBm.

The M5e-Compact units support power from 10 dBm to 23 dBm.

FAULT_MSG_INVALID_FREQ_RECEIVED - 104h

Cause

A message was received by the reader to set the frequency outside the supported range

Solution

Make sure the host does not set the frequency outside this range or any other locally
supported ranges.

FAULT_MSG_INVALID_PARAMETER_VALUE - 105h

Cause

The reader received a valid command with an unsupported or invalid value within this
command.

For example, currently the module supports two antennas, 1 and 2. If the module
receives a message with an antenna value other than 1 or 2, it returns this error.

Solution

Make sure the host sets all the values in a command according to the values published in
this document.

Advertising
This manual is related to the following products: