Get read tx power (62h), Get write tx power (64h), Release version 1.0.34 – ThingMagic M5e-Compact User Manual

Page 241

Advertising
background image

Release Version 1.0.34

Appendix D: Deprecated and Modified Commands

241

The response to the Read Data command for the GEN2 protocol has the following
format.

Read Tag Data Response

The length (M) of the data returned is twice the WordCount value in the original command
because the return packet length is counted in bytes.

Get Read TX Power (62h)

The Get Read TX Power command returns the current TX power for reading tags, in
centi-dBm:

Microprocessor reply is similar to the Set Read TX Power command. In this example,
0x09C4 corresponds to 2500, which is 25.00 dBm. The default read power is set to 30
dBm:

Get Write TX Power (64h)

The Get Write TX Power command gets the current power level used for TX write
commands:

FF

M

28

00

00

01

M

??

??

SOH

Length

OpCode

Status

Data

CRC

FF

00

62

1D

6D

SOH

Length

OpCode

CRC

FF

02

62

00

00

09

C4

1F

B7

SOH

Length

OpCode

Status

Power in centi-dBm

CRC