Solution, Fault_general_tag_error – 40ah, Cause – ThingMagic M5e-Compact User Manual

Page 224: Fault_data_too_large – 40bh, Fault_protocol_invalid_kill_password – 40ch

Advertising
background image

Protocol Faults

224

Appendix C: Error Messages

Solution

Make sure that the address specified is within the scope of the tag data address space
and available for the specific operation. The protocol specifications contain information
about the supported addresses.

FAULT_GENERAL_TAG_ERROR – 40Ah

Cause

This error is used by the M5e GEN2 module. This fault can occur if the read, write, lock,
or kill command fails. This error can be internal or functional.

Solution

Make a note of the operations you were performing and contact ThingMagic at

http://

support.thingmagic.com

FAULT_DATA_TOO_LARGE – 40Bh

Cause

A command was received to Read Tag Data with a data value larger than expected or it is
not the correct size.

Solution

Check the size of the data value in the message sent to the reader.

FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch

Cause

An incorrect kill password was received as part of the Kill Tag (26h) command.

Solution

Check the password.

Advertising