ThingMagic M5e-Compact User Manual

Page 129

Advertising
background image

Application Tag Commands

Command Set

129

BlockReadLock Command Fields

An example BlockReadLock single tag command is:.

Field

Value

Description

Length

0x09

Number of bytes in the command following the OpCode.

OpCode

0x2D

Gen2 Tag Specific Command.

Time Out

[2 bytes]

Command timeout in milliseconds.

Chip Type

0x05

Alien Higgs3.

Tag Singulation
Fields

| Select

Option

[1 byte]

• bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub

command follows this byte, and before the remaining

Tag

Singulation Fields

Sub Command

0x0009

BlockReadLock

Tag Singulation
Fields

| Select

[Address, Data
Length, Data]

[n bytes]

The remaining fields from the

Tag Singulation Fields

Note:

Optional depending on the value of Select Option.

Current Access
Password

[4 bytes]

The Access Password for the tag. If Access Password is currently set
and the tag locked, the Access Password must be passed to allow
writing.

Command Lock
Bits

[1 byte]

Setting a bit value = 1 locks the corresponding User Memory Words.
The least significant bit is bit0:
bit7=1 Locks User words 0 thru 3
bit6=1 Locks User words 4 thru 7
bit5=1 Locks User words 8 thru 11
bit4=1 Locks User words 12 thru 15
bit3=1 Locks User words 16 thru 19
bit2=1 Locks User words 20 thru 23
bit1=1 Locks User words 24 thru 27
bit0=1 Locks User words 28 thru 31

Note:

Depending on the tag memory configuration all 32 Words of

User memory may not be available.

FF

25

2D

03

E8

05

44

00 09

00

00

00

20

10

11 22

SOH

Length

OpCode

Timeout (ms)

Chip

Type

Option

Sub

Cmd

Select Data Address

Select
Length

Selct
Data

Advertising