Get regulatory hop time – ThingMagic M5e-Compact User Manual

Page 176

Advertising
background image

Get Application Commands

176

Command Set

The reply format is similar to the Set Frequency Hop Table command. The length must
be set to a multiple of four, and a maximum of 62 hop frequencies is returned. The
frequencies are returned in kHz. Thus, frequency #1 (0xDC370) corresponds to 902,000
kHz:

Get Regulatory Hop Time

Adding the option field and specifying option=0x01 returns the hop frequency in use.

Get Regulatory Hop Time Command Fields (Option = 0x01)

Get Regulatory Hop Time Response Fields (Option = 0x01)

FF

00

65

1D

6A

SOH

Length

OpCode

CRC

FF

0C

65

00

00

00

0D

C3

70

00

0D

F6

38

00

0E

26

12

60

B2

SOH

Length

OpCode

Status

Freq #1

Freq #2

Freq #3

CRC

Field

Value

Description

Length

0x01

Number of bytes after OpCode

OpCode

0x65

Get Frequency Hop Table

Option

0x01

Indicates the Regulatory Hop Time will be passed.

Field

Value

Description

Length

0x05

Number of bytes after OpCode

OpCode

0x65

Get Frequency Hop Table

Status

[2 bytes]

Status

Option

0x01

Indicates the Regulatory Hop Time will be passed.

Regulatory Hop
Time

[4 bytes]

The hopping interval, in milli-seconds, currently used for the
defined hop table.