Examples – ThingMagic M5e-Compact User Manual

Page 86

Advertising
background image

Application Tag Commands

86

Command Set

Read Tag Single Get EPC and Metadata Response Fields

Examples

An example command requesting AntennaID and Timestamp

Field

Length

Value

SOH

1 byte

0xFF

Length

1 byte

Based on data returned

OpCode

1 byte

0x21

Status

2 bytes

Status of command

Options

1 byte

As sent in request

Metadata Flags

2 bytes

Metadata contained in response

Read Count

1

1 byte

Tag EPC/Antenna Read Count

RSSI

1

1 byte

Return Signal Strength Indicator

Antenna ID

1

1 byte

Antenna ID, 4 MSBs for TX and 4
LSBs for RX

Frequency

1

3 bytes

Frequency in kHz

Timestamp

1

4 bytes

RTC Timestamp

RFU

1

2 bytes

Reserved for Future Use - ThingMagic
Only

Protocol ID

1 byte

Protocol ID of tag (always 0x05 for
M5e/M5e-C)

Tag Data Length

2 bytes

Size of tag data to follow. Always
0x0000 for Read Tag Single

EPC ID

N bytes

Tag EPC.

Tag CRC

2 bytes

Tag EPC CRC

CRC

2 bytes

Message CRC

1 - Conditionally returned depending on the Metadata Fields specified in the request.

Advertising