Application Tag Commands

Command Set

111

Status

2 bytes

0x0000 for success. Otherwise see

Appendix C: Error Messages

Options

1 byte

As sent in request

Metadata Flags

2 bytes

Metadata contained in response

Read Count

1

1 byte

Tag EPC/Antenna Read Count

RSSI

1

1 byte

Return Signal Strength Indicator

Antenna ID

1

1 byte

Antenna ID, 4 MSBs for TX and 4
LSBs for RX

Frequency

1

3 bytes

Frequency in kHz

Timestamp

1

4 bytes

RTC Timestamp

RFU

1

2 bytes

Reserved for Future Use - ThingMagic
Only

Protocol ID

1

1 byte

Protocol ID of tag (always 0x05 for
M5e/M5e-C)

Tag Data Length

1

2 bytes

N/A - always zero for Read Tag Data.

Tag Data

N bytes

Number of bytes of Tag Data
requested.

CRC

2 bytes

Message CRC

1 - Conditionally returned depending on the Metadata Fields specified in the request.