ThingMagic M5e-Compact User Manual

Page 54

Advertising
background image

Host-to-Reader Communication

54

Overview of the Communication Protocol

The fields are summarized in the following table.:

Field

Length

Description

Header (Hdr)

1 byte

Defines the start of the packet. Equal to 0xFF

1

Data Length (Len)

1.Minimum packet length is 5 bytes; the maximum packet length is 255 bytes.

1 byte

Defines the length,

N

, of the data field contained in the

packet.

Command

1 byte

Specifies the command that the reader is to execute.

Data

N

bytes

(0 to 250)

Defines the binary data required by the reader for use with a
command. This could, for example, represent transponder
data to be written. The length,

N

, can vary between 0 and

250 bytes.

CRC-16 Checksum
(CRC HI, CRC LO)

2 bytes

CRC-16 checksum (high order byte first). CRC polynomial is
CCITT CRC-16, with a preload of 0xFFFF. This does not fully
specify the operation of the CRC, see

CCITT CRC-16 Cal-

culation

.

Advertising