Get Application Commands

Command Set

169

Get Application Commands

The Get commands listed in the following table are used to get settable parameters from
the Mercury Embedded module. All of the commands have a data length of zero, and
return data or a fault code.

Applications Commands – Get

Error Status Codes

FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h

FAULT_MSG_INVALID_PARAMETER_VALUE - 105h

FAULT_AHAL_TRANSMITTER_ON – 502h

OpCode

Command Name

Bootloader

App Firmware

0x10

Get Hardware Version (10h)

Y

Y

0x61

Get Antenna Configuration (61h)

N

Y

0x62

Get Read TX Power (62h)

N

Y

0x63

Get Current Tag Protocol (63h)

N

Y

0x64

Get Write TX Power (64h)

N

Y

0x65

Get Frequency Hop Table (65h)

N

Y

0x66

Get User GPIO Inputs (66h)

N

Y

0x67

Get Current Region (67h)

N

Y

0x68

Get Power Mode (68h)

N

Y

0x69

Get User Mode (69h)

N

Y

0x6A

Get Reader Configuration(6Ah)

N

Y

0x6B

Get Protocol Configuration (6Bh)

N

Y

0x6C

Get Reader Statistics (6Ch)

N

Y

0x70

Get Available Protocols (70h)

N

Y

0x71

Get Available Regions (71h)

N

Y

0x72

Get Current Temperature (72h)

N

Y