FAULT_PROTOCOL_KILL_FAILED - 40Eh

Cause

Attempt to kill a tag failed for an unknown reason

Solution

Check tag is in RF field and the kill password.

FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh

Cause

Attempt to operate on a tag with an EPC length greater than the Maximum EPC length
setting.

Solution

Call

Set Reader Configuration(9Ah)

to set the Max EPC to 496 bits..

FAULT_PROTOCOL_INVALID_EPC – 410h

Cause

This error is used by the M5e GEN2 module indicating an invalid EPC value has been
specified for an operation. This fault can occur if the read, write, lock, or kill command
fails.

Solution

Check the EPC value that is being passed in the command resulting in this error.

FAULT_PROTOCOL_INVALID_NUM_DATA – 411h

Cause

This error is used by the M5e GEN2 module indicating invalid data has been specified for
an operation. This fault can occur if the read, write, lock, or kill command fails.